Bki LGF-FC Gas Pressure Fryer Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Friteusen Bki LGF-FC Gas Pressure Fryer herunter. BKI LGF-FC Gas Pressure Fryer User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Gas Pressure Fryer

Gas Pressure Fryer MODELS LGF, LGF-F, & LGF-FC Installation and Operation Manual Serial Numbers 137733 and higher

Seite 2 - WARRANTY

Gas Pressure Fryer Introduction Be Prepared for Emergencies Be prepared for fires, injuries, or other emergencies. Keep a first aid kit and a

Seite 3 - Table of Contents

Gas Pressure Fryer Introduction Safety Labels 9

Seite 4 - Introduction

Gas Pressure Fryer Introduction 10

Seite 5 - Specific Precautions

Gas Pressure Fryer Installation Installation Inspection for Shipping Damage It is the owners’ responsibility to file all freight claims with the d

Seite 6 - Safe Work Practices

Gas Pressure Fryer Installation Location and Clearance Install your fryer in a well-ventilated area. This will ensure that the gas burns properly

Seite 7

Gas Pressure Fryer Installation Failure to restrain the fryer could allow it to move, causing hot shortening to spill out, or a possible break in

Seite 8

Gas Pressure Fryer Installation Overfilling the fryer pot with shortening could lead to serious injury. Ensure that the fryer pot is filled with

Seite 9

Gas Pressure Fryer Operation Operation Controls and Indicators Refer to the figure and table below for an explanation of the fryer’s controls and

Seite 10 - Do Not Smoke Near The Fryer

Gas Pressure Fryer Operation 16 Item Description Function 1 Pressure Gauge Indicates the pressure inside the pot. 2 Spin Handle Used to tigh

Seite 11 - Safety Labels

Gas Pressure Fryer Operation 17 Item Description Function 8 A, B, C, D preset buttons These buttons are used to save and recall preset cycle an

Seite 12

BKI LIMITED WARRANTY PO Box 80400 • Simpsonville, SC 29680-0400 • USA (864) 963-3471 • Toll Free: (800) 927-6887 • Fax: (864) 963-5316 Asia  Europe

Seite 13 - Installation

Gas Pressure Fryer Operation 18 Care of the Shortening Solid shortening should always be returned to the filter vat while in the liquid state. If

Seite 14 - Installation Procedure

Gas Pressure Fryer Operation LGF and LGF-F Operation Start-Up (LGF and LGF-F) 1. Make sure the main drain valve is closed. 2. Fill pot with s

Seite 15 - Initial Test and Adjustment

Gas Pressure Fryer Operation Cooking (LGF and LGF-F) Do not open the drain valve or the fill valve while the fryer is under pressure. Serious bur

Seite 16 - Gas Conversion Instructions

Gas Pressure Fryer Operation fryer for an hour or more, turn the thermostat down to 150 F and close the lid. 15. When you have finished frying f

Seite 17 - Operation

Gas Pressure Fryer Operation 22 Table 1. System Programming Procedure STEP ACTION DISPLAY COMMENTS 1 Press the FILTER/OFF/FRY switch to FRY. L

Seite 18

Gas Pressure Fryer Operation Product Programming Use the following figure and table to set a maximum of eight product programs. The product progra

Seite 19

Gas Pressure Fryer Operation 24 Table 2. Product Programming Procedure STEP ACTION DISPLAY COMMENTS 1 Press the FILTER/OFF/FRY switch to FRY.

Seite 20 - Care of the Shortening

Gas Pressure Fryer Operation 25 STEP ACTION DISPLAY COMMENTS 13 Repeat steps 5-12 when programming stages 2, 3, 4 and 5 for Electric and Gas a

Seite 21 - LGF and LGF-F Operation

Gas Pressure Fryer Operation Start-Up (LGF-FC) 1. Make sure the main drain valve is closed. 2. Fill pot with shortening to about one inch bel

Seite 22 - Cooking (LGF and LGF-F)

Gas Pressure Fryer Operation 4. Carefully drop the chicken in the shortening one piece at a time starting with thighs and drumsticks. The fryer is

Seite 23 - LGF-FC Operation

Gas Pressure Fryer Table of Contents 1 Table of Contents Table of Contents ...

Seite 24

Gas Pressure Fryer Operation 28 Recipes Fried Onion Rings 1. Take frozen onion rings from freezer or bread fresh onion rings with Imperial bread

Seite 25 - Product Programming

Gas Pressure Fryer Operation 29 Whole Turkey (12 to 14 pounds) 1. Rinse and bread turkey with Imperial breading. 2. Place turkey into fryer bask

Seite 26

Gas Pressure Fryer Operation Operation After Gas or Power Outage The fryer may shut off automatically if the gas supply is interrupted or the powe

Seite 27

Gas Pressure Fryer Maintenance Maintenance Failure to comply with the maintenance below could result in a serious accident. Do not over-tighte

Seite 28 - Cooking (LGF-FC)

Gas Pressure Fryer Maintenance Safety Pop Valve Procedure The safety pop valve should be blown under pressure periodically to prevent the seat fro

Seite 29

Gas Pressure Fryer Maintenance Filtering Procedure Breaded foods require frequent filtering. An excess amount of breading left in the fryer pot wi

Seite 30 - Recipes

Gas Pressure Fryer Maintenance To refill the pot through the rinse hose, use the steps below:  Make certain that the rinse hose is connected to

Seite 31

Gas Pressure Fryer Maintenance  Position the FILTER/OFF/FRY switch to FILTER and shortening will automatically pump into the pot.  After 1 mi

Seite 32 - Normal Shutoff

Gas Pressure Fryer Maintenance 3. CLOSE the drain and fill the fryer pot with HOT water to the shortening level fill mark. Do not overfill by allo

Seite 33 - Maintenance

Gas Pressure Fryer Maintenance Filter Pad Replacement The filter pad must be replaced daily. If the shortening has a milky color when it is pumped

Seite 34 - Safety Pop Valve Procedure

Gas Pressure Fryer Introduction Introduction The LGF Pressure Fryer is compact, attractive and functional in design. It is constructed of a stainl

Seite 35 - Filtering Procedure

Gas Pressure Fryer Maintenance 38 Troubleshooting Refer to the table below for troubleshooting information. Problem Cause Possible Solution Pr

Seite 36

Gas Pressure Fryer Appendix A 39 Appendix A Gas Control Valve Instructions

Seite 37 - Boil-Out Procedure

P.O. Box 80400, Simpsonville, S.C. 29680-0400, USA http://www.bkideas.com Made and printed i

Seite 38

Gas Pressure Fryer Introduction Specific Precautions Lids for LGF Pressure Fryers manufactured prior to May 27, 1980 (or units with serial number

Seite 39 - Filter Pad Replacement

Gas Pressure Fryer Introduction Safe Work Practices Do Not Store Or Use Anything Flammable Near The Fryer Your pressure fryer is powered by eit

Seite 40 - Troubleshooting

Gas Pressure Fryer Introduction 5 Keep The Floor Around Your Fryer Clean Of Shortening Make sure to keep the floor around your fryer clean of s

Seite 41 - Appendix A

Gas Pressure Fryer Introduction Always Make Sure The Lid Hook Is Latched When Closing The Fryer To make sure the lid hook is latched properly, p

Seite 42

Gas Pressure Fryer Introduction Keep Away From The Vent Hot steam escapes from the vent continuously when you are using your fryer. You could be

Verwandte Modelle: LGF-F Gas Pressure Fryer

Kommentare zu diesen Handbüchern

Keine Kommentare