2.1.7.0 STRAP TABLE
Select m3, l, US Gal, Ft3, bbl,
M3/h, Ft3/h, kg,
Metric Tons, US Tons
2.1.7.1 VOLUME UNIT
Liter [l]
Unit for conversion values ("volume table").
The selected unit is used to define the strapping table values.
0 to 20 points 2.1.7.2 INPUT TABLE
0
(i.e. no volume table)
This function defines the strapping table.
The maximum number of points is 20.
Each subsequent value must be greater than the previous one.
The length and volume units can be changed later without affecting the settings in the
table. Calculations are done automatically in the instrument.
2.1.7.3 DELETE TABLE This function deletes the strapping table.
Function (Fct.) Input Range Description
2.2.0 TESTS
2.2.1 TEST OUTPUT Select 4 mA, 12mA, 20 mA, Other This function allows the current output to be tested.
The output can be set to one of the listed values.
With a reference ammeter, the calibration of the current output can be verified.
2.3.0 SERVICE Restricted access factory configuration menu. These parameters may be
accessed via Fct. 3.2 “Specialist PSW (password).
3.0 ACCESS RIGHTS
Yes or No.
Enter 9-character code if “Yes”.
3.1 MAINTENANCE
PSW
No
Disables the access lock on the configuration menu.
The password must contain exactly 9 characters.
E, R or U are used only. The password is displayed in a scrambled format.
It allows NIVELCO to decode the password in case it was forgotten.
3.2 SPECIALIST PSW See NIVELCO Service centre or MicroTREK 2-wire Service Manual for code.
4.0 WATCH STATUS This function displays the status of the device.